Non-Destructive Testing in Western Australia

On-site and workshop testing for welds, fabrications and in-service equipment. Tell us what you’re working on and we’ll help scope the right inspection.

Request an NDT Quote

Tell us what needs testing and where the job is.

Accredited. Certified. Trusted.

Recognised standards for testing, workplace safety and quality management.

NATA Accredited

NATA Accredited

ACTS’s High Wycombe testing site is accredited to ISO/IEC 17025 for the activities in its published scope.

View Published NATA Scope
ISO 45001 – Health & Safety

ISO 45001 – Health & Safety

A strong commitment to workplace safety, risk management and continuous improvement.

ISO 9001 – Quality Management

ISO 9001 – Quality Management

Certified quality systems focused on consistency, reliability and customer satisfaction.

Five Ways to Check Your Asset

Choose the method in your specification, or ask us which test fits the material, the component and the defect you’re looking for.

UT

Ultrasonic Testing

Internal flaws and wall thickness

Ultrasonic testing uses sound waves to check for internal discontinuities and measure remaining wall thickness. It suits welds, steel sections and in-service equipment where the condition below the surface matters.

  • Weld integrity checks
  • Pipe and vessel thickness readings
  • Corrosion and material-loss surveys

Advanced Ultrasonic Testing

Phased Array Ultrasonic Testing (PAUT). Scans welds from multiple angles to detect and size flaws.

Time-of-Flight Diffraction (TOFD). Uses diffracted sound to detect and measure internal weld flaws.

MT / MPI

Magnetic Particle Testing

Surface cracking in ferromagnetic steel

Magnetic particle testing highlights surface and some near-surface discontinuities in ferromagnetic materials. It is a practical choice for checking weld toes, steel fabrications and components where fatigue cracking is suspected.

  • Weld toes and heat-affected zones
  • Steel fabrications and forged components
  • Fatigue checks on lifting components
PT / DPT

Dye Penetrant Testing

Surface-breaking flaws in non-porous materials

Dye penetrant testing reveals flaws open to the surface. It works on clean, non-porous materials such as stainless steel and aluminium, including components that cannot be examined with a magnetic method.

  • Stainless steel and aluminium welds
  • Machined surfaces and flange faces
  • Surface-breaking cracks and porosity
ECT

Eddy Current Testing

Surface and near-surface flaws in conductive metals

Eddy current testing uses an electromagnetic probe to check electrically conductive materials. Ask about high-frequency eddy current for surface flaw detection, including through suitable coatings where the agreed technique allows.

  • Surface crack checks on conductive metals
  • Fabricated components and weld areas
  • Selected coated surfaces where suitable
VT

Visual Testing

Visible defects, wear and weld condition

Visual testing gives you a documented view of accessible surfaces. Inspectors can use lighting, gauges, magnification or remote viewing tools to check weld profile and look for corrosion, wear, damage or distortion.

  • Weld profile and visible surface condition
  • In-service checks for damage and corrosion
  • Remote viewing where direct access is limited

Industries We Support

ACTS provides workshop and on-site NDT for fabrication, shutdowns and in-service equipment across Western Australia.

Mining & Minerals

Shutdown work, sustaining maintenance and process plant.

Request a Quote

Oil & Gas

Welds, pressure equipment, piping and associated assets.

Request a Quote

Power & Renewables

Plant components and structural fabrications.

Request a Quote

Refining & Manufacturing

New welds, repairs and component quality checks.

Request a Quote

Marine & Civil

Steelwork, structural components and in-service assets.

Request a Quote

How It Works

  1. Share Equipment and Site Details

    Tell us what needs testing, how many items there are, where the job is and what you need to check.

  2. Discuss Scope and Access

    Talk through testing needs, available records, isolation, shutdown and site access requirements.

  3. Agree on the Quote and Schedule

    Confirm the scope, quotation and testing date before work proceeds.

  4. Testing and Reporting

    ACTS completes the testing and provides the agreed report.

Perth-Based. Working Across WA.

ACTS supports workshop jobs in the Perth metro area and site work across regional WA. For remote projects, share the mobilisation requirements, site access and shutdown dates with your enquiry.

Before You Book

Have a specification or a shutdown date? Send it through when you enquire.

Request a Quote
Which Method Should I Book?

If you have a specification, send it with your enquiry. Otherwise, tell us the material, component, areas of concern and what you need to find. ACTS can discuss the appropriate method and whether more than one check is needed.

Can You Test on Site in Regional WA?

ACTS is based in High Wycombe and supports jobs across Perth and regional Western Australia. Share the location, access arrangements and dates so the team can confirm mobilisation and scheduling.

What Will the Report Include?

The agreed scope determines the deliverables. Reports typically capture the component or area tested, the method, the results and any relevant readings, indications or photographs. Send the project’s reporting requirements when you request a quote.

Is My Job Covered by NATA Accreditation?

Coverage depends on the method, material and technique in the published scope. ACTS can confirm whether your specific work and reporting requirements fall within that scope when quoting.

Can You Help With Shutdowns or Urgent Work?

Call ACTS with the site, job scope and required date. The team can confirm availability, access requirements and when the report can be issued.

Tell Us What Needs Testing

Send the asset details and site location, or call ACTS to talk through the job.

(08) 6385 8080
admin@assetconformity.com.au
Unit 5, 1120 Abernethy Road
High Wycombe WA 6057

Request an NDT Quote

Tell us what needs testing and where the job is.

Call ACTSRequest a Quote